1762 S Dixie Hwy #2
Crete, IL 60417
708-758-5070

Our Top Cities


Local Reviews
for hoffman estates, il

Rated 5.0 out of 5 stars based on 5 customer reviews

Client

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

Bob was great. Knowledgeable and friendly.


Response from Trenchless Innovations Inc.:

Thank you so much for your feedback! We're thrilled to hear that Bob provided a knowledgeable and friendly experience during the inspection of your underground air ducts. We'll be sure to pass along your kind words to him. If there's anything else we can assist you with, please don’t hesitate to reach out!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Extremely pleasant to work with

For as much as I disliked even having to do this work, the entire team at Trenchless made me feel comfortable with my decision and made it a pleasant experience. They answered all my questions and listened to my concerns with patience. I do believe the work was extremely necessary and will be beneficial. With limited providers, I was relieved they were so great to work with and the disruption was minimal. I'd recommend to people if they have rusted vents, stop delaying because the rust and stress just grows and just choose Trenchless.


Response from Trenchless Innovations Inc.:

Sherri, thank you so much for your review and for your kind words! We are so happy to hear you had a pleasant experience with our team and that they took good care of you! We hope you're enjoying the benefits of our trenchless technology and loving the cleaner, healthier air in your home. Thank you for choosing Trenchless Innovations for your air duct repair. We are always here if you have any further questions.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful Service

True professionals throughout the whole process. Highly recommend this company!!!


Response from Trenchless Innovations Inc.:

Thank you for your review, Kathy! We are delighted to hear you had a pleasant experience with our team. Thank you for choosing Trenchless Innovations for your air duct repair. He hope you're enjoying the cleaner and healthier air in your home!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Amazing service


Response from Trenchless Innovations Inc.:

Thanks for sharing your rating with us and the community.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for hoffman estates, il

Jim D.

Jim D. Job Checkin

Just wrapped up pipe epoxy coating job in Hoffman Estates. Prepped pipes by sand-blasting to remove scale & corrosion. Applied 2 coats of industrial-grade epoxy (blue series 7000). Coating thickness measures 8-10 mils throughout - perfect! Pressure tested system @ 60 PSI for 1 hr - zero leaks. System restored to service after 24hr cure time. Customer very satisfied with work quality & minimal disruption. Left site clean & tidy.


Bob S.

Bob S. Job Checkin

Televised ducts under slab portion. Of house. Ducts are metal in an area that is an addition to the house. The rest are concrete. The metal ducts are very rusted and need to be replaced due to the configuration. After that the ducts should then be spray lined with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete with metal fittings and connects that are showing signs of rust and allowing dirt and debris into the system. Suggest spin cast mortaring metal fittings then spray lining ducts with Duct Armor duct lining material.


Kevin W.

Kevin W. Job Checkin

12-12-2024: reconnected duct pipes that were removed to fix plumbing and rebuilt wall of plenum box that was removed to fix plumbing, also cleaned all underground duct work in preparation for trenchless casting. 12-16-2024 Applied spin cast mortar to all underground duct work. 12-18-24 Applied first application of duct armor to all underground ductwork and furnace box. 12/30/24 Applied second application of duct armor to all underground ductwork and furnace box.


Josh R.

Josh R. Job Checkin

Hydraulic cemented small holes in air duct system Applied duct armor over cracked lining


Josh R.

Josh R. Job Checkin

12/20/24 applied second coat of duct armor product to approx. 115' of 6" air ducts Televised air duct system as per the customers request Collected cash down payment for balance


Josh R.

Josh R. Job Checkin

Televised and cleaned furnace box and register vent by back door in kitchen. Repaired furnace box and register vent by backdoor in kitchen with hydraulic cement. Applied duct armor to furnace box and register vent by back door.


Bob S.

Bob S. Job Checkin

Televised ducts to confirm footages for spin casting and lining.


John R.

John R. Job Checkin

Did a video inspection of the 2” kitchen sink drain line from under kitchen sink found hole at bottom of 2” drain near tee connection, bottom of pipe completely missing line was holding water but ran clear water to get good view of missing pipe. Too many connections and turns in 2” run to line needs to be broke up and replaced. 4” line appears to be in good condition. Recommended replacing all 2” pipe underground while hole is open and cabinets are removed to prevent having to remove and open floor again in future.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts with metal fitting that are rusted as well as the plenum under the furnace. Will provide a proposal for spin cast mortaring the metal fittings the spray lining the system with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts and see they are filled with water that has an odor. Ran watrer in the kitchen sink and see water movement in the ducts. Ran water in the tub and also see water movement in the ducts. Suggest a plumber repairs the kitchen sink and the tub line. Will provide a proposal for spin cast mortaring and spray lining the ducts after water issue is resolved.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete with metal fittings. Provide proposal to repair plenum then spray line ducts with Duct Armor.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor in basement addition room. Ducts are galvanized metal ducts and are extremely rusted and deteriorated. Suggest spin cast mortaring to restore the structure then spray lining with Duct Armor duct lining material.


Bob S.

Bob S. Job Checkin

Televised ducts under slab floor. Ducts are concrete ducts with metal fittings. The plenum is very rusted as are some of the register opening. Will provide a quote for spray lining system with DuctAtmor duct lining material.


Josh R.

Josh R. Job Checkin

Cleaned all underground duct work. Applied first application of duct armor to all underground duct work.